價(jià)格
電議
型號
MS8607A
品牌
所在地
廣東省 深圳市
更新時間
2019-02-02 19:45:01
瀏覽次數(shù)
次
其他推薦產(chǎn)品
首頁| 關(guān)于我們| 聯(lián)系我們| 友情鏈接| 廣告服務(wù)| 會員服務(wù)| 付款方式| 意見反饋| 法律聲明| 服務(wù)條款
Anritsu | MS8607A 數(shù)字移動無線發(fā)射機(jī)測試儀|日本安立|MS8607A|綜合測試儀
:日本安立 | Anritsu
·DMR 發(fā)射器測試儀MS8607A
·300 kHz to 3 GHz
·FEATURES
·Built-in spectrum analyzer, analog measurement functions, and power meter
·內(nèi)置頻譜分析儀, 模擬測量函數(shù),和功率計(jì)
·Multisystem support
·多系統(tǒng)支持
·Wideband CDMA analysis
·寬帶CDMA分析
·IQ (Baseband) signal analysis
·IQ(基帶)信號分析
·DMR Transmitter Tester
·MS8606A
·300 kHz to 3 GHz
·DMR傳送器測試儀 MS8606A
·300 kHz to 3 GHz
·For CDMA, PDC measurement
·對于CDMA的配電測量
·High-speed, high precision measurement
·高速高精度的測量
·Built-in spectrum analyzer and AF measurement function
·內(nèi)置頻譜分析儀和音頻測量功能
Starting characteristics:≤5*10^-8/day(after 10 minutes of warm-up,comparedto the frequency after 24-hour warm-up)
Aging rate:≤2*10^-8/day(0°to 50℃,compared to the frequency after 24-hourwarm-up)
Temperature characteristics:≤5*10^-8/day(0°to 50℃,compared to the frequencyat 25℃)
External reference input:10 or 13MHz(±1 ppm),2 to 5Vp-p
Level range:0 to +40dBm
Measurement accuracy:±10%(after zero calibration)
S
p
e
c
t
r
u
m
a
n
a
l
y
z
e
r
Setting range:0 to 3GHz(band:0),10MHz to 3GHz(band:1)*Setting resolution:1Hz
HPF:1.6 to 3GHz,On/Off
Frequency accuracy
Display accuracy:±(display frequency x reference frequency accuracy+spanx span accuracy)
Normal marker:Same as span accuracy
Frequency span
Setting range:0Hz,10kHz to 3GHz(band:0);0Hz,10kHz to 2.99GHz(band:1)
Span accuracy:±2.5%
RBW(resolution bandwidth)
Setting range:300Hz to 1MHz(3dB BW,1-3 sequence)
Accuracy:±2%(300Hz to 300kHz),±10%(1MHz)
Selectivity(60dB:3dB):≤5:1
VBW(video bandwidth):3Hz to 100kHz(1-3 sequence),through
Sideband noise:≤-95dBc/Hz(1GHz,10kHz offset),≤-115dBc/Hz(1Ghz,100kHz offset)
Continuous average power:+40dBm(MAIN connector),+20dBm(AUX connector)
DC voltage:0V
Average noise level(RBW:1kHz,VBW:10Hz):
≤-90dBm(MAIN connector,10MHz to 1GHz,input attenuator:20dB)
≤-90dBm+f[Ghz](MAIN connector,>1Ghz,input attenuator:0dB)
≤-110dBm+f[Ghz](AUX connector,10MHz to 1Ghz,input attenuator:0dB)
≤-110dBm+f[GHz](AUX connector,>1GHz,input attenuator:0dB)
Residual response:≤-70dBm(MAIN connector,input attenuator:20dB),≤-90dBm(AUXconnector,input attenuator:0dB)
Total level accuracy
MAIN connector:±1.5dB(reference level:+10.1 to +40dBm,at 0 to -50dB of referencelevel)
AUX connector:±1.5dB(reference level:-9.9 to +20dBm,at 0 to -50dB of referencelevel)
Reference level
Setting range:-60 to +50dBm(MAIN connector),-80 to +30dBm(AUX connector)
Setting resolution:0.1dB
Accuracy:±0.5dB(MAIN connector,+10.1 to +40dBm),±1.0dB(MAIN connector,-80to -10dBm),
±0.5dB(AUX connector,-9.9 to +20dBm),±1.0dB(AUX connector,-80 to -10dBm)
RBW switching error:±0.1dB(referenced to RBW:3kHz)
Frequency response:±0.5dB[referenced to 100MHz,input attenuator:30dB(10dBfor AUX);temperature range:18°to 28℃]
Log linearity:±0.5dB(0 to -50dB,RBW:≤1MHz),±1.0dB(0 to -70dB(0 to -70dB,RBW:≤1kHz)
*10MHz to 2.2GHz,reference level:≥0dBm(MAIN connector);≥-20dBm(AUX connector)
2nd harmonic distortion:≤-55dBc(10 to 100MHz),≤-60dBc(100 to 1500MHz)*Atmixer input level:-30dBm
Trigger switch:FREERUN,TRIGGERED
Trigger source:WIDE IF VIDEO (3 dB bandwidth:≥20MHz,trigger slope:RISE/FALL)
EXT(trigger level:TTL level,trigger slope:RISE/FALL)
Trigger delay
Setting range:0μs to 100ms;Resolution:2μs
Gate delay,gate width
Setting range:2μs to 100ms;Resolution:2μs
Signal search:PEAK-CF,PEAK-REF
Zone marker:NORMAL,DELTA
Marker-function:MARKER-CF,MARKER-REF,ZONE-SPAN
Peak search:PEAK,,NEXT RIGHT pEAK,NEXT LEFT PEAK
Measurement
Noise power:dBm/Hz,dBm/ch
Occupied bandwidth:Power N% method,X dB down method
Adjacent channel power
Reference measurement:Total power/reference level method
Display method:Channel specified display(2 channels X 2),graphic display
Average power of burst signal:Average power within the specified time rangeof the time domain waveform
Detection mode:POS PEAK,NEG PEAK,SAMPLE
Display function:TRACE A,TRACE B,TRACE TIME
Storage funciton:NORMAL,VIEW,MAX HOLD,MIN HOLD,Average,CUMULATIVE<>
Frequency range:300kHz to 3Ghz;Level range:0 to +40dBm(MAIN connector);Accuracy:±10%(afterzero point calibration)
Power measurement(narrow band)
Frequency range:10MHz to 3GHz
Input level:0 to +40dBm(MAIN connector),-40 to +20dBm(AUX connector)
Accuracy:±10%(MAIN connector,after calibration with internal wide band powermeter)
±1dB(AUX connector,reference level:≥-12dBm,18°to 28℃,after calibration)
Linearity: ±0.3dB(0 to -30dB)
Freqeuncy measurement
Frequency range:10MHz to 3Ghz
Input level:-20 to +40dBm(MAIN connector),-40 to +20dBm(AUX connector)
Resolution:1Hz
Accuracy:±(reference oscillator accuracy+10Hz) *IF frequency counting (bandwidth:±30kHz)
FM measurement
Frequency range:10MHz to 3Ghz
Input level:-20 to +40dBm(MAIN connector),-40 to +20dBm(AUX connector)
Deviation:0 to 20kHz
Demodulation frequency:30Hz to 20kHz
Accuracy:1% of indicated value+residual FM(demodulaiton frequency:1kHz)
Frequency response:±0.5dB(demodulation frequency:referenced to 1kHz)
Residual FM:8Hz-rms(demodulation frequency:0.3 to 3kHz)
Distortion:0.3%(demodulation frequency:1kHz,demodulation bandwidth:0.3 to3kHz,deviation:5kHz)
Filters(3dB cut-off):HPF(50Hz,300Hz),LPF(3kHz,15kHz)
φM measurement
Frequency range:10MHz to 3Ghz
Input level:-20 to +40dBm(MAIN connector),-40 to +20dBm(AUX connector)
Deviation:0 to 10rad
Demodulation frequency :300Hz to 3kHz
Accuracy:1% of indicated value+residual φM(demodulation frequency:1kHz)
Frequency response:±0.5dB(demodulation frequency:referenced to 1kHz)
Residual φM:0.01 rad-rms (demodulation bandwidth:0.3 to 3kHz)
Distortion:0.5%(demoduation frequency:1kHz,demodulation bandwidth:0.3 to3kHz,deviation:5rad)
Filters(3dB cut-off):HPF(50Hz,300Hz),LPF(3kHz,15kHz)
Hard copy:Enables data hard copy of the display through a parallel interface(printer:ESC/Pcompatible printer).
GPIB:This instruments in specified as a device,can be controlled from externalcontroller(excluding power switch).
Interface functions:SH1,AH1,T6,L4,SR1,RL1,PP0,DC1,DT1,C0,E2)
Parallel interface:Conforms to the Centronics.Outputs printing data to printer.D-sub25-pin connector(female)
RS-232C:All functions except power switch controlled by external controller(baudrate:1200,2400,4800,9600bps)
EN50082-1:1992
Harmonic current emissions:EN61000-3-2:1995 Class A
訂貨信息
J0576B
J0768
J0017F
F0014
W1367AE
MS8607A-01
Digital Mobile aRadiO TRANSMITTER Tester
Standard accessories(for mainframe)
Coaxial cord(N-P.5D-2W.N-P),1m
Coaxial adapter(N-J.TNC_P)
Poewer cord 2.6m
Fuse,6.3A
MS8607A operation manual:
Options
AF measurement(audio analzer,AF oscillator
MX860702A
MX860704A
W1368AE
W1369AE
W1379AE
CDMA Measurement Software
PDC Measurement Software
W-CDMA Measurement Softwae
Standard accessories(for measurement software)
MX860701B operation manual 1copy
MX860702A operation manual 1copy
MX860704A operation manual 1copy
MS2663C
J0127C
J0769
J0040
MN1607A
MA1612A
J0395
J0007
J0008
B0329D
B0331D
B0332
B0333D
B0334D
Spectrum Anylyzer
Spectrum Anylyzer
Optional accessories
Coaxial cord(BNC-P.RG-58A?U.BNC-P),0.5m
Coaxial adapter(BNC-J.TNC-P)
Coaxial adapter(N-P.BNC-J)
Coaxial switch(DC to 3GHz,50Ω,external controllable)
Four-point junction pad(5 to 30000MHz)
Fixed attenuator for high power(30dB,30W,Dc to 8GHz)
GPIB cable,1m
GPIB cable,2m
Front cover(1MW5U)
Front handle(2pcs/1set)
Front handle(2pcs/1set)
Joint plate(4 pcs/set)
Rack moun kit
Carrying case(hard type)